A Novel Approach for Approximating High-Altitude Electromagnetic Pulse Induced Fields in Cavities Based on Superposition of Decaying Oscillating Plane Waves
Article information
Abstract
To address the challenge of high-altitude electromagnetic pulse (HEMP) infiltration into equipment cavities, which threatens internal electronics, conventional simulation methods like the finite integral technique (FIT) often suffer from high computational cost and low efficiency. This study proposes a novel approximate method based on the superposition of decaying oscillating plane waves (DOPW-S) to efficiently simulate the intra-cavity pulsed electromagnetic environment. Simulation results demonstrate that the DOPW-S method produces waveform characteristics similar to FIT and shows good agreement in the cumulative probability distribution of electric field peaks, verifying its feasibility for simulating complex cavity fields. Furthermore, the DOPW-S method reduces computation time by 95.93% compared to FIT.
I. Introduction
High-altitude electromagnetic pulse (HEMP) refers to the transient electromagnetic wave generated by prompt gamma rays during a high-altitude nuclear explosion (typically assumed at altitudes >30 km). It is characterized by high field amplitude, extensive spatial coverage, and wide frequency bandwidth [1]. HEMP couples into the interior of the equipment cavity through apertures, and forms a decaying pulsed field based on the resonance effect. It has the characteristics of multi-directional propagation and being dominated by high-frequency energy, posing a serious threat to the sensitive electronic devices inside the cavity [2]. Therefore, it is particularly necessary to carry out research on the effect of electronic devices in the environment of coupled pulsed field inside the cavity.
Simulation calculation is an effective method to be used in the research on the effect of HEMP on electronic. It can not only significantly reduce the experimental cost and experimentation period, but also simulate complex electromagnetic environments under controllable and repeatable conditions. Through simulation calculation, we can obtain the distribution characteristics of the pulsed field environment inside the cavity under HEMP excitation. Therefore, it can be used to study the coupling response law of the cables inside the cavity. As an exploratory step before the experiment, simulation calculation can provide a theoretical basis and effective guidance for subsequent experimental research.
In the research field of electromagnetic coupling into cavity with aperture, there are many research works on the theoretical analysis and numerical method. Finite-difference time-domain method [3], the finite element method [4], the discontinuous Galerkin time-domain method [5, 6], etc., have been widely applied to precisely simulate the coupling of electromagnetic waves through the aperture and their interaction with the cavity. Translation finite integral technique (FIT)-based time-domain solvers (CST Studio Suite) are widely regarded as reliable benchmark tools for such problems due to their excellent adaptability to complex geometries and broadband calculation capability. However, actual equipment (such as aircraft and automobiles) features cavities of diverse shapes that are densely packed with numerous cables and devices, rendering accurate electromagnetic modeling extremely challenging. Critically, the computational accuracy of full-wave methods like FIT is highly dependent on refined mesh generation; to accurately resolve the resonant field distribution inside complex cavities, the massive meshes required will incur substantial memory consumption and time costs. Even if substantial resources are devoted to building precise models, the ensuing exorbitant computational and time costs are still prohibitive. In addition, the pulsed fields inside cavities are highly sensitive to boundary conditions, where any minor modification can lead to significant variations in results. Therefore, it is of great significance to develop a novel method that can effectively handle real-world complex cavities, drastically reduce computational costs while maintaining the credibility of key field characteristics, and realize the approximate simulation of pulsed fields inside cavities.
In the cavity electromagnetic environment and reverberation chamber electromagnetic environment, Moglie F, based on the ideal reverberation chamber plane wave integral expression proposed by Hill [7], adopted the plane wave superposition method to effectively solve the problem of construction of the steady-state field environment in the reverberation chamber [8], which ensures the simulation accuracy and reduce its complexity. Based on the plane wave spectrum theory, this method expresses the electromagnetic field in the reverberation chamber as the superposition of a finite series of plane waves, thereby providing an accurate and efficient calculation approach for the simulation of the steady-state field inside the cavity.
Following the method by Moglie F, we analyzed the environmental characteristics of the transient coupled pulsed field in the cavity, proposed a method for simulating the coupled pulsed field environment in the cavity based on superposition of decaying oscillating plane waves (DOPW-S), and elaborated on the setting methods of parameters such as frequency, decay factor, incident angle and phase of the superposed decaying oscillating plane waves. Then, the proposed method is compared with the FIT method to verify the effectiveness and efficiency of the method. Finally, the application prospect of the DOPW-S method is discussed.
II. Problem Description
1. HEMP Excitation Source
The HEMP environment consists of three phases: the early-time (E1), intermediate-time (E2), and late-time (E3) high-altitude electromagnetic pulses. E1 is dominated by high-frequency components (>1 MHz), E2 by medium-frequency components (102–103 Hz), and E3 by low-frequency components (<102 Hz) [9, 10]. This study focuses on the field environment when the early-time high-altitude electromagnetic pulse couples into the cavity. The E1 waveform specified in the IEC standard is selected [11], which can be regarded as a plane wave in the far-field region. Its time-domain and frequency-spectrum waveforms are shown in Fig. 1 and Fig. 2, respectively, and the time-domain and frequency-domain expressions are as follows:
where E0 = 50 kV/m (electric field peak), k = 1.3 (correction coefficient), α = 4 × 107 s−1, β = 6 × 108 s−1, α and β are the pulse parameter, ω represents angular frequency.
2. The Distribution Characteristics of Intra-cavity Pulsed Field
When HEMP irradiates the equipment cavity, it can couple into the cavity through apertures. To study the characteristics of the pulsed field environment inside the cavity, we used the FIT method of the time-domain solver in CST Studio Suite to construct a rectangular cavity with dimensions of 250 cm × 300 cm × 320 cm, a cavity wall thickness (w) of 0.1 cm, and a material conductivity (σ) of 3.56 × 107 S/m. The aperture is a square aperture with L = 50 cm located at the geometric center of the 300 cm × 320 cm wall surface. To accurately simulate the radiation characteristics of aperture coupling, the open-space boundary condition Open (add space) was adopted and the mesh type was set to hexahedral mesh. The interaction between the HEMP and the metal shielding cavity with apertures is illustrated in Fig. 3. P0 denotes the central position of the cavity, while P1–P8 represent the positions of the eight vertices inside the cavity.
The simulation calculation time is set to 0–2,000 ns, and the frequency range is 0–1 GHz. The HEMP polarization angle (ζ) is 45°, the azimuth angle (γ) is 30°, and the elevation angle (η) is 0°. Taking the center of the cavity as the coordinate origin, the calculated time-domain and frequency-spectrum waveforms of the electric field at the cavity center P0(0, 0, 0) are shown in Fig. 4.
Coupled pulsed field of HEMP in the cavity: (a) time-domain and frequency-spectrum waveforms of electric field in the x-direction, (b) time-domain and frequency-spectrum waveforms of electric field in the y-direction, and (c) time-domain and frequency- spectrum waveforms of electric field in the z-direction.
As can be seen in Fig. 4, the time-domain waveform of the electric field at the center of the cavity shows an overall decaying oscillation. The x and y directions are dominated by HEMP polarization, with a main pulse followed by decaying oscillation, which can last for several microseconds, much longer than the duration of the HEMP waveform. From the frequency-spectrum waveform, it can be seen that the energy transmitted into the cavity is mainly the high-frequency energy of HEMP, which is concentrated at the resonant frequency points of the cavity. As the frequency increases, the resonant frequency points become increasingly dense, which is consistent with the cavity resonance theory.
To further clarify the distribution characteristics of the spatial field in the cavity, the electric field waveforms at three different positions in the cavity, namely P8(−60, −90, 100), P7(−90, −100, −80), and P2(110, 130, 90), were calculated. The time-domain and frequency-spectrum waveforms are shown in Fig. 5.
The pulse fields at different locations within the cavity: (a) x-axis time-domain electric field, (b) y-axis time-domain electric field, (c) z-axis time-domain electric field, and (d) electric field frequency spectrum.
It can be seen from Fig. 5 that the time-domain waveforms of the electric field at different positions in the cavity all show the characteristics of decaying oscillation as a whole. The frequency-domain energy is still concentrated at the resonant frequency points, and the frequency-spectrum waveform shows a trend of first rising and then falling. This is because the aperture can be equivalent to a high-pass filter, making it difficult for low-frequency energy to enter the cavity through the aperture, and the decrease in the latter part is due to the fact that the HEMP energy itself decaying in the high-frequency band.
Since the energy of the intra-cavity pulsed field is mainly high-frequency, and the internal structure of the practical cavity is very complex, tiny structural differences will lead to huge changes in the distribution of internal resonant frequency points. Therefore, it is difficult to accurately obtain the pulsed field distribution in the actual cavity even by using numerical simulation methods.
3. Feasibility Analysis of DOPW-S for Simulating Pulsed Field in Complex Cavities
Based on the previous analysis and referring to Hill’s plane wave superposition method [7], this article proposes a method based on DOPW-S, forming a simulation calculation method for the coupled pulsed field in the cavity in a statistical sense.
The premise of plane wave superposition is that the electromagnetic waves in the cavity are in an over-moded state. The energy of HEMP coupled into the cavity is mainly high-frequency energy, so it is possible to construct the coupled pulsed field environment in the cavity by drawing on the plane wave superposition theory. Therefore, the following analyzes how to approximately simulate the pulsed field in the cavity using the statistical coverage method.
It is assumed that there is an aperture on the irradiated surface of the cavity, and the shielding performance of the cavity material is sufficiently good. The aperture can be regarded as the main coupling path of HEMP, which has the characteristic of high-pass filtering, making it difficult for low-frequency components to couple into the cavity. After the transmitted wave enters the cavity, it is mainly affected by cavity resonance, forming a high-frequency decaying oscillating wave. However, the resonant frequency of real complex cavities is difficult to calculate. Therefore, the DOPW-S method and the distribution law of resonant frequencies in actual cavities are the main factors determining the characteristics of the intra-cavity pulsed field environment.
Take a rectangular cavity as an example. The distribution of cavity resonant frequencies is calculated according to:
where c denotes the speed of light in vacuum, a, b, l represent the cavity’s dimensional lengths, m, n, p are the half-wave numbers along their respective cavity dimensions.
Fig. 6 shows the resonant frequency distributions in two cavities with volumes of 250 cm × 300 cm × 320 cm and 350 cm × 400 cm × 520 cm. It can be seen from the figure that the larger the cavity size, the lower the first resonant frequency, as the frequency increases, the interval between resonant frequencies becomes increasingly dense, that is, the frequency density is proportional to the square of the frequency.
The first resonant frequency of a small cavity is already in the relatively dense region of the resonant frequencies of a large cavity. Therefore, the frequency-domain energy range in the large cavity can cover that of the small cavity. In addition, since the aperture size of a real complex cavity is smaller than the boundary size of the cavity, the effective low-frequency components of the pulsed field in the real complex cavity will be higher than the first resonant frequency of the cavity, and the resonant frequencies corresponding to the energy spectrum range of the transmitted electromagnetic pulse are relatively dense (multi-mode region). Due to the more dense resonant spectrum of the large cavity in the high-frequency range, when the resonant frequencies in both the large and small cavities are sufficiently dense, their field environments will be very close.
Therefore, when using the DOPW-S method to simulate the pulsed field in a real complex cavity, calculating with a cavity larger than the size of the cavity shell can obtain a pulsed field environment close to that in the actual cavity.
In real-world engineering structures, the physical size of the aperture is usually much smaller than the overall size of the structure itself. If the aperture is designed too large, a large amount of HEMP energy will couple into the cavity, posing a serious threat to the normal operation of the electronic devices inside the cavity. Therefore, this article focuses on electric small apertures on electrically large-sized cavities to study how to simulate the decaying oscillating pulsed field formed by HEMP in the cavity.
III. Parameter Configuration for DOPW-S
The plane wave spectrum theory is the superposition of plane waves with a single frequency but different amplitudes and phases [12]. However, after HEMP couples into the cavity, it manifests as a decaying oscillating pulsed field with multiple frequency points coexisting. Each decaying oscillating plane wave represented by a frequency has different amplitudes and phases. Therefore, it is necessary to reasonably set various parameters of the decaying oscillating plane waves to correctly simulate the pulsed field environment in the cavity.
As a transient field, HEMP couples into the cavity through the aperture. Due to the absence of continuous energy input, the energy at each resonant frequency essentially oscillates in a damped manner until it dissipates. Therefore, the intra-cavity pulsed field can be superimposed in the form of decaying oscillating plane waves. The superimposed decaying oscillating plane waves are set as exponentially decaying sine waves, whose waveform is shown in Fig. 7, and their expression is as follows:
where K denotes the amplitude, α is decay factor, fmnp is resonant frequency, and Φ is phase angle.
Since the coupled pulsed field in the cavity has multiple resonant frequency points coexisting, the frequency of the superimposed plane waves is no longer a single frequency. In addition to the frequency, incident angle, phase angle and amplitude of the decaying oscillating plane waves, the setting method of the decay factor also needs to be considered.
1. Frequency
After HEMP couples into the cavity through the aperture, it is affected by cavity resonance, and only frequency components that meet its resonant frequency can exist. Hence, the frequency of the superimposed plane waves is set to the resonant frequency of the cavity, and the number of plane waves (M) corresponds to all resonant modes within the calculated frequency range. The resonant frequency of the cavity is calculated according to Eq. (3).
2. Incident Angle, Phase Angle and Polarization Angle
Each resonant frequency fmnp corresponds to a specific unstable standing-wave pattern within the cavity. For a given mode (m, n, p), the dominant direction of its wave vector is given by:
where kx, ky, and kz represent the wave vector components in the x, y, and z directions, respectively.
After HEMP couples into the cavity, the skin depth of electromagnetic waves decreases with increasing frequency, while the surface resistance increases with increasing frequency, leading to an increase in conductor loss power as the frequency rises. Moreover, the high-frequency modes of electromagnetic waves correspond to shorter wavelengths, resulting in rapid energy dissipation at the aperture, while the corresponding low-frequency modes decaying more slowly. This serves as the distribution principle for the M columns of plane waves over the 4π solid angle.
In the spherical coordinate system, the incident angle of any column of plane waves can be represented by the elevation angle θ and the azimuth angle ϕ, as shown in Fig. 8. The direction of the coordinate axes in the figure is consistent with that in Fig. 3. Among them, θ ∈ [0, π] and ϕ ∈ [0,2π] . In the early stage, dominated by high-frequency modes, the elevation angles of plane waves are concentrated near the initial incident direction. For the k-th high-frequency mode fk , the distribution of its elevation angle is:
where N represents Gaussian distribution, and σθ decreases with the increase of frequency. Its calculation formula is:
where The fmax represents the maximum resonant frequency. To concentrate the high-frequency components moderately, π/4 is selected.
Correspondingly, the low-frequency modes decay relatively slowly, and the elevation angles of electromagnetic waves gradually spread to the full range, with their distribution directions tending to be randomized. Their distribution is:
The aperture shape studied in this article has high symmetry, therefore, the azimuth angles ϕ of all modes are uniformly sampled as U(0,2π), but adjustments can be made according to the mode symmetry:
where U represents the uniform distribution, which is applicable to the symmetric mode of rectangular cavities. m and n represent the number of half-waves along the directions of the a and b side lengths in the cavity, respectively.
Because HEMP undergoes multiple reflections after entering the cavity, the polarization angles and phase angles of incoming waves at different positions in the cavity can be regarded as having a certain randomness. Therefore, the phase angles and polarization angles are set to be randomly sampled within the range of 0–2π.
3. Amplitude
The aperture can be regarded as a high-pass filter, whose cutoff frequency fc is determined by the aperture size. When f < fc , electromagnetic waves can hardly pass through the aperture, when f > fc , electromagnetic waves can pass through the aperture completely. Its amplitude response is set as follows:
where w is the thickness of the cavity wall. Then the frequency-domain amplitude response of HEMP after passing through the aperture is:
The amplitude of the M columns of plane waves is calculated based on the spectral waveform of HEMP after passing through the aperture. The spectral waveform of HEMP after passing through the aperture is shown in Fig. 9. It can be seen from the figure that the trend of the spectral waveform of HEMP after passing through the aperture is basically consistent with the spectral waveform trend calculated above.
4. Decay Factor
The decay factor is closely related to the quality factor of the cavity. The Q-value of the cavity mainly consists of two parts: conductor loss and radiation loss. The reciprocal of the total Q-value is equal to the sum of the reciprocals of the two parts:
where Qc is conductor loss, Qr is radiation loss.
The conductor loss is related to the conductivity of the cavity material and the electromagnetic wave mode. The Qc values for TE and TM modes can be calculated respectively according to the formula given by Harrington [13]. According to the Bethe small aperture theory, the aperture can be equivalently regarded as electric dipoles and magnetic dipoles to calculate the Qr value of radiation loss [14].
The waveform of the intra-cavity pulsed field exhibits exponential decay as e−αt, thus the energy within the cavity also decays exponentially as e−2αt. Therefore, the relationship between the decay factor α and the quality factor Q value can be obtained as:
where ω is angular frequency. Take the above steps, and we can determine various parameters of the M columns of superimposed plane waves. The M columns of decaying oscillating plane waves are distributed over the 4π solid angle, and the intra- cavity pulsed field is simulated after superposition. The flowchart of the method implementation is shown in Fig. 10.
IV. Case Study Verification
1. Determining the Model to Verify the Feasibility of the DOPW-S Method
To preliminarily verify the feasibility of the DOPW-S method, the cavity in Section II is taken as an example. The HEMP polarization angle ζ is 90°, azimuth angle γ is 45°, and elevation angle η is 0°. The calculation time is 0–200 ns, and the frequency range is 0–1 GHz. First, the empty cavity model is taken as the research object. For the empty cavity model, the resonant frequency calculated by the DOPW-S method is the rectangular cavity resonant frequency obtained from Eq. (3). Taking the electric field time-domain and spectral waveforms at the position P8(−60, −90, 100) as examples, a comparison is made with the calculation results of the FIT, as shown in Fig. 11.
Comparison of DOPW-S and FIT calculation results: (a) x-axis time-domain electric field, (b) y-axis time-domain electric field, (c) z-axis time-domain electric field, and (d) electric field frequency spectrum.
It can be seen from Fig. 11 that the overall trend and magnitude of the electric field time-domain waveforms calculated by the DOPW-S method and the FIT method are basically consistent, and the overall trend of the frequency spectrum both shows a trend of first rising and then falling. This preliminarily indicates that the DOPW-S method is feasible for simulating the pulsed field environment in the cavity. Given that the random polarization and incidence angles adopted in the method of this paper preclude the derivation of an exact solution at any specific position, it is thus necessary to verify the statistical characteristics of the pulsed fields inside the cavity.
Therefore, the electric field time-domain waveforms at nine positions in the cavity, namely P0(0, 0, 0), P5(100, −80, −120), P2(110, 130, 90), P1(120, 130, −100), P6(60, −100, 100), P8(−60, −90, 100), P4(−70, 80, 90), P3(−80, 90, −100), P7(−90, −100, −80), are taken as examples. When the HEMP polarization angle ζ is 0° and 45°, the elevation angle η is 0°, and the azimuth angle γ is from 0° to 80° in steps of 10°, the maximum absolute values of the electric field time-domain waveforms at the nine positions are taken and compared with the FIT calculation results. The peak cumulative probability distribution of the absolute values of the electric field time-domain waveforms and the total calculation time are shown in Fig. 12.
Cumulative distribution of time-domain peaks of electric field in three directions and total calculation time: (a) x direction, (b) y direction, and (c) z direction.
It can be seen from Fig. 12 that the time-domain peaks of the electric field in the three directions have a good degree of agreement with both the FIT calculation results and the standard normal distribution. Moreover, the calculation time is 94.57% faster than that of the FIT method. When a large number of cavity resonant modes are excited, leading to a complex and statistically uniform field distribution inside the cavity, the statistical behavior of multiple spatially independent sampling points can be effectively described by the standard normal distribution with a certain size of samples. Therefore, the cumulative distribution function of the standard normal distribution is used to compare with the statistical distribution of the evaluated peak fields, which is further combined with the theories of over-moded cavities and reverberation chambers.
To further verify the feasibility of the DOPW-S method in simulating the pulsed field in practical complex cavities, the cavity size in Section II is used as an example. Cables and metal devices are arranged in the cavity to simulate the scenario in a real cavity, as shown in Fig. 13.
A copper wire with a radius of 1.5 mm is added, and the coordinates of the two ends of the wire are (−140, −150, −120) and (140, −150, −120), respectively. Additionally, three cubic metal blocks with a conductivity (σ) of 1.59 × 107 S/m are placed—two with edge lengths of 30 cm and one with 60 cm. The geometric centers of the metal blocks are located at (110, −130, 100), (75, −135, −15), and (−110, −120, 0), respectively. The HEMP azimuth angle γ is 0°, elevation angle η is 0°, and polarization angle ζ is 30°. The calculation time is 0–200 ns, and the frequency range is 0–1 GHz.
The metal blocks placed in the cavity to simulate devices cause a change in the cavity’s resonant frequency, and its effective low-frequency components will be higher than the first resonant frequency of the empty cavity. Based on the analysis in Section II, the first resonant frequency of the small cavity is already in the relatively dense region of the large cavity’s resonant frequencies, and the frequency-domain energy range in the large cavity can cover the small cavity. Therefore, the resonant frequency calculated by the DOPW-S method is that of the 350 cm × 400 cm × 520 cm cavity. To avoid redundant low-frequency components during calculation, the DOPW-S method needs to start calculation from the first resonant frequency of the small cavity. Taking the electric field time-domain and spectral waveforms at the cavity center as examples, a comparison is made with the FIT calculation results, as shown in Fig. 14.
Comparison of DOPW-S and FIT calculation results: (a) x-axis time-domain electric field, (b) y-axis time-domain electric field, (c) z-axis time-domain electric field, and (d) electric field frequency spectrum.
It can be seen from Fig. 14 that the characteristics of the electric field time-domain and spectral waveforms calculated by the DOPW-S method and the FIT method are basically consistent. At the same time, this can verify the analysis in Section II that the large cavity can contain the electromagnetic environment in the small cavity. The consistency between the DOPW-S method and the FIT calculation results in terms of time-domain waveform characteristics and frequency-domain components further indicates the feasibility of the DOPW-S method in simulating the pulsed field environment in complex cavities.
Take the electric field time-domain waveforms at the nine positions in the cavity mentioned above as examples again. The HEMP azimuth angle γ is set from 0° to 80° in steps of 10°, the elevation angle η is 0°, and the polarization angles ζ are 0° and 45°. The maximum absolute values of the electric field time-domain waveforms at the nine positions are extracted and compared with the FIT calculation results. The peak cumulative probability distribution of the absolute values of the electric field time-domain waveforms and the total calculation time are shown in Fig. 15.
Cumulative distribution of time-domain peaks of electric field in three directions and total calculation time: (a) x direction, (b) y direction, and (c) z direction.
Fig. 15 shows that the time-domain peaks of the electric field in the three directions are highly consistent with both the FIT calculation results and the standard normal distribution, and the calculation time is 95.93% faster than that of the FIT method. When the internal layout of the cavity becomes complex, the calculation time of FIT increases significantly, but the calculation efficiency of DOPW-S is even higher compared with FIT, which reflects the advantage of the DOPW-S method in quickly calculating the pulsed field in complex cavities.
The DOPW-S method is an efficient statistical approximation for rapidly assessing the internal field statistics in overmoded cavities under wideband excitation. Its limitations should be noted: it reproduces statistical field distributions rather than deterministic, phase-accurate time-domain solutions; its accuracy diminishes at low frequencies (with sparse modes) and it is optimized for single dominant apertures, requiring caution for multi-aperture cases.
V. Conclusion
Based on the distribution characteristics of the intra-cavity pulsed field, in this paper, we proposed an approximate simulation method for the HEMP coupling field environment in the cavity using the DOPW-S. By correlating the key parameters of the superimposed plane waves with the propagation characteristics of the intra-cavity pulsed field, this method can be used to effectively construct the pulsed field distribution in the cavity. Simulation results show that the overall trends of the time-domain waveform and spectral waveform characteristics of the electric field in the cavity simulated by the DOPW-S method are consistent with those by the FIT method. Further analysis indicates that when the DOPW-S method achieves statistical coverage of the resonant frequency points of the real complex cavity, it can effectively approximate the pulsed field environment in the actual cavity. The more complex the internal layout of the cavity, the higher the calculation efficiency of this method compared with the FIT method. This study provides an efficient calculation approach for the coupling response analysis of cables at multiple positions in the cavity, and offers new ideas for the research on the experimental methods of the HEMP effect of electronic devices in the cavity.
References
Biography
![]()
Haizhe Zhong, https://orcid.org/0009-0009-6240-0134 is a doctoral student in the Rocket Force University of Engineering, Xi’an, China. Specializing in the research of high-altitude electromagnetic pulse effects.
![]()
Jiantao Liang, https://orcid.org/0009-0002-2733-9293 is an associate professor at the Rocket Force University of Engineering, Xi’an, China. Research direction is electromagnetic compatibility design.
![]()
Ying Zhan, https://orcid.org/0009-0003-9392-3604 received the MS degree from Northwestern Polytechnical University, Xi’an, China, in 2006. She is an associate professor in the Rocket Force University of Engineering, Xi’an, China. Her research areas include Functional Linguistics Foreign Language Teaching and Researching.
![]()
Xiyao Yu, https://orcid.org/0009-0009-6450-8448 is a doctoral student at the Rocket Force University of Engineering, Xi’an, China. The research focus is on the irradiation damage of energetic materials.