J. Electromagn. Eng. Sci Search

CLOSE


J. Electromagn. Eng. Sci > Volume 26(5); 2026 > Article
Lee, Son, and Yang: Robust Envelope-Based Signal Preprocessing for Sub-Terahertz Imaging

Abstract

An envelope-detection-based signal preprocessing technique is proposed to robustly enhance the signal-to-noise ratio (SNR) in subterahertz (sub-THz) imaging systems. Conventional peak-based amplitude extraction is highly sensitive to high-frequency noise and detector-induced direct-current (DC) offset drift, resulting in unstable intensity estimation and degraded image uniformity. The proposed approach directly extracts the signal envelope from the sampled waveform, providing noise-resilient and drift-tolerant amplitude detection without computationally intensive post-processing. The method is implemented in a sub-THz imaging platform employing a 0.18-μm CMOS plasmonic detector. Experimental results from 0.15-THz raster-scanned images of a metallic test target demonstrate an SNR improvement of approximately 9 dB compared with peak detection, along with enhanced spatial uniformity and image fidelity. Owing to its low computational overhead, the proposed technique is well suited for real-time and embedded sub-THz imaging applications.

I. Introduction

Terahertz (THz) imaging has attracted considerable attention for a wide range of applications, including nondestructive evaluation, security screening, and material characterization, owing to its ability to penetrate optically opaque media and provide spectrally sensitive contrast [1–3]. Despite these advantages, the practical performance of THz imaging systems is often limited by a low signal-to-noise ratio (SNR), which degrades image quality and restricts reliable identification of fine structural or material features. In many experimental systems, the SNR is inherently low due to weak received signal levels, detector nonidealities, and susceptibility to environmental and electronic disturbances.
To address this challenge, numerous studies have investigated methods for improving the SNR of THz imaging systems through hardware optimization, signal modulation schemes, and post-processing techniques. In imaging systems employing plasmonic detectors, a common approach to amplitude extraction is to identify the peak value of the time-domain waveform acquired at each detector channel [4–6]. Although peak detection is straightforward and computationally efficient, it is highly sensitive to high-frequency noise and direct-current (DC) offset drift. DC offset drift arises from multiple sources, including temperature variations, device self-heating, bias instability, and low-frequency electronic interference [7]. This drift introduces slow baseline fluctuations that are superimposed on the desired modulated THz waveform. While such baseline variations occur at frequencies much lower than the THz modulation, they become particularly detrimental when peak-based amplitude estimation is employed.
Peak detection inherently relies on a single maximum sample referenced to the instantaneous baseline. As a result, even a small baseline shift can directly translate into a significant error in the extracted peak amplitude, especially under weak-signal conditions typical of sub-THz imaging [8–10]. Unlike random high-frequency noise, DC drift produces a systematic amplitude bias rather than a zero-mean fluctuation, thereby distorting the measured intensity distribution. Moreover, in raster-scanned imaging systems, DC offset drift varies gradually over time and across measurement positions, resulting in pixel-dependent amplitude bias [11]. Consequently, the reconstructed image may exhibit artificial contrast variations, spatial nonuniformity, and degraded fidelity that do not originate from the target itself but from measurement instability. Such drift-induced artifacts cannot be effectively removed by simple averaging, since the drift is correlated across measurements rather than random. Therefore, DC offset drift represents a critical bottleneck for reliable amplitude recovery and consistent image formation when conventional peak detection is used. These limitations highlight the need for signal preprocessing techniques that are robust against noise and baseline drift while preserving the intrinsic spatial resolution of THz images [12]. In particular, preprocessing methods operating directly on the measured waveform are desirable, as they can enhance measurement reliability without requiring additional hardware complexity or extensive post-reconstruction processing.
In this paper, an envelope-detection-based signal preprocessing method is presented to improve the quality of sub-THz imaging. The detected waveform, which contains a modulated THz signal superimposed with noise and DC offset components, is processed to extract its envelope. By directly estimating the waveform envelope rather than relying on instantaneous peak values, the proposed method provides noise-resilient and drift-tolerant amplitude extraction at the signal acquisition stage. This operation effectively suppresses high-frequency noise and mitigates DC offset drift, yielding a stable and low-noise amplitude signal suitable for image reconstruction. As a result, the proposed method enhances image clarity and spatial uniformity while maintaining the original signal amplitude characteristics inherent to the sub-THz measurement.

II. Envelope-Based Detection Method

In THz imaging systems, the SNR of an image is commonly evaluated based on the contrast between the maximum and minimum detector output levels within a single image frame. This definition provides a direct measure of image quality and contrast. In the imaging system considered in this work, a plasmonic complementary metal–oxide–semiconductor (CMOS) detector converts incident terahertz radiation into a DC output voltage proportional to the received signal intensity [13]. Although this DC voltage represents the detector response, it is inherently vulnerable to low-frequency noise components, including DC noise and flicker noise, which can significantly degrade the effective SNR.
To suppress low-frequency noise, the THz source is periodically modulated between ON and OFF states at a modulation frequency fm, thereby shifting the detector response to a higher-frequency band where low-frequency noise contributions are reduced. In practical measurements, the modulated detector output is sampled at a sampling frequency fs. During the ON state, the sampled waveform contains the modulated terahertz response superimposed with noise, whereas during the OFF state, it consists solely of intrinsic noise components. Accurate extraction of the amplitude difference between the ON and OFF states is therefore critical for reliable image reconstruction.
Fig. 1 illustrates the conventional peak detection method and the proposed envelope-based detection approach applied to the sampled waveform. In the conventional method, the maximum and minimum peak values are identified separately for the ON and OFF states, and their average values are computed. The detector output is then obtained by subtracting the averaged OFF-state value from the averaged ON-state value. While this approach is simple, it is highly sensitive to noise-induced outliers. Peaks that deviate significantly from their true levels can bias the averaging process, leading to underestimation of large peaks and overestimation of small peaks, ultimately resulting in amplitude distortion and reduced image uniformity.
To overcome this limitation, an envelope-based detection method is employed. Rather than relying on discrete peak values, the proposed approach captures the overall amplitude variation of the waveform by extracting its upper and lower envelopes. By averaging multiple points along these envelope curves, the influence of noise spikes and outliers is substantially reduced, enabling more robust amplitude estimation for each image pixel. In particular, the proposed method computes the signal envelope using a Hilbert-transform-based analytic signal formulation, which provides a mathematically well-defined amplitude representation for narrowband modulated waveforms [14]. Let the sampled detector waveform at a given pixel be expressed as
(1)
x [n]=s [n]+w [n],
where s[n] denotes the modulated terahertz response and w[n] represents the additive noise and baseline component. The analytic signal z[n] corresponding to x[n] is defined as
(2)
z [n]=x [n]+jx^ [n],
where x̂ [n] is the Hilbert transform of x[n], given by
(3)
x^ [n]=H{x [n]}.
The instantaneous envelope e[n] is then obtained as the magnitude of the analytic signal:
(4)
e [n]= ∣z [n]∣=x [n]2+x^ [n]2.
Unlike peak detection, which depends on a single extreme sample, the Hilbert envelope provides a continuous amplitude estimate that is inherently less sensitive to impulsive noise and sampling jitter. Therefore, envelope averaging yields a statistically more stable amplitude measure for both ON and OFF modulation intervals.
Fig. 2 outlines the procedure for generating the final image from the raw sampled data. For each pixel, the acquired time-domain waveform is first segmented into ON and OFF states according to the modulation signal. The envelope e[n] in (4) is computed for each segment, and the mean envelope values of the ON and OFF states are calculated as
(5)
EON=1NON∑n∈ONe [n],
(6)
EOFF=1NOFF∑n∈OFFe [n],.
The pixel amplitude is then obtained by subtracting the OFF-state envelope mean from the ON-state envelope mean:
(7)
A=EON-EOFF.
This differential envelope operation effectively suppresses low-frequency drift and noise floor variations while preserving the intrinsic modulation-induced amplitude response of the detector. By arranging the extracted amplitudes into an N × N matrix, the final terahertz image is reconstructed. Because the proposed method operates directly on the sampled waveform with minimal computational overhead (Hilbert transform and averaging), it is well-suited for real-time sub-THz imaging systems requiring robust pixel-level amplitude extraction. Compared with conventional demodulation approaches, the proposed envelope-based preprocessing requires no additional reference channel and provides a compact front-end solution for plasmonic detector imaging arrays.

III. Results and Discussion

1. Measurement Setup

Fig. 3 shows the experimental setup used to acquire 0.15-THz raster-scanned images with the proposed preprocessing method. A continuous-wave (CW) signal at 12.5 GHz was generated and then frequency-multiplied to 0.15 THz using a VDI signal generator extension (SGX) module. To enable amplitude extraction under noise suppression, a 200-Hz square-wave modulation signal was applied to the SGX module, producing alternating ON-OFF excitation states. This frequency was chosen to avoid interference from the power-line frequency (60 Hz) and its harmonics while shifting the detected signal away from the low-frequency noise region. It also maintains consistency with the modulation scheme used in our previous experimental setup [4]. The output power of the VDI SGX source module is specified as approximately 18 dBm according to the manufacturer’s datasheet. The modulated 0.15 THz signal is radiated through a rectangular horn antenna with a gain of 25 dBi. The detector output waveform was sampled using a data acquisition (DAQ) board at a sampling rate of 8 kS/s. The distance between the THz source and the target sample, as well as that between the sample and the detector, was fixed at 10 mm. The employed plasmonic detector IC was fabricated using a 0.18-μm CMOS process and occupies a chip area of 0.79 × 0.70 mm2 [15–17]. This compact detector architecture provides a practical platform for evaluating waveform-level preprocessing techniques in sub-THz imaging systems.

2. Comparison of Peak and Envelope Detection

To illustrate the signal preprocessing workflow, time-domain waveforms were recorded from a single pixel under 200-Hz modulated THz excitation without a target sample. Fig. 4(a) and 4(b) show the ON- and OFF-state waveforms processed using the conventional peak detection method. Because peak detection relies on discrete extrema, the extracted peak traces are strongly affected by noise-induced outliers. In some cases, noise-induced spikes can produce instantaneous peaks in the OFF-state waveform that exceed the lower peaks observed in the ON state. Consequently, the estimated ON-OFF amplitude difference becomes unstable, leading to biased intensity extraction and degraded pixel reliability.
In contrast, Fig. 4(c) and 4(d) show the corresponding results obtained using the proposed envelope-based detection method. By computing smooth upper and lower envelopes through Hilbert-transform-based analytic signal processing, the proposed approach suppresses high-frequency fluctuations and mitigates baseline drift effects. As a result, the extracted ON-OFF amplitude difference exhibits significantly improved stability, confirming that envelope-based preprocessing yields more reliable detector response estimation in the presence of practical noise sources.

3. Imaging Experiment and Quantitative Performance

To further validate the proposed method in an imaging scenario, a copper-tape target was prepared in the shape of the letter “K,” as shown in Fig. 5(a). The tape widths of the vertical and diagonal strips were 12 mm and 10 mm, respectively, and the scanning area was defined as 50 mm × 50 mm. Fig. 5(b) and 5(c) present the reconstructed images obtained using peak detection and envelope-based detection, respectively. The measured SNR was 13.3 dB for conventional peak detection and 22.3 dB for the proposed envelope-based approach, corresponding to an improvement of approximately 9 dB. In addition to the increased SNR, the proposed method produces sharper boundaries along the copper tape edges and significantly reduces intensity variations in spatially uniform regions, demonstrating enhanced image fidelity and contrast consistency. Beyond global SNR improvement, the proposed method provides substantial gains in spatial stability. The normalized standard deviation within the uniform copper-tape region decreases from 0.065 (peak detection) to 0.024 (envelope detection), corresponding to a reduction of approximately 63%. Furthermore, the pixel coefficient of variation is reduced from 18.5% to 6.8%, indicating a ×2.7 improvement in amplitude stability across the reconstructed pattern. These results confirm that the proposed preprocessing approach effectively suppresses pixel-level fluctuations that directly limit spatial uniformity in raster-scanned sub-THz imaging.

4. Complexity-Efficient Improvement Compared with Prior Techniques

Table 1 summarizes representative preprocessing and enhancement techniques reported in THz imaging systems [18, 19]. The comparison focuses on signal preprocessing strategies applied to detected waveforms and is therefore largely independent of the absolute terahertz carrier frequency. It provides a qualitative overview of algorithmic structures and reported performance improvements rather than a strict quantitative benchmark across different experimental conditions. Advanced post-processing approaches such as wavelet denoising and ROI-based reconstruction can provide improved image contrast, but they typically require multi-stage decomposition, adaptive thresholding, and computationally intensive reconstruction steps after full-frame acquisition. In particular, the methods reported in [18] and [19] involve six and more sequential processing stages, including transform-domain analysis, coefficient selection, iterative filtering, and reconstruction. While these approaches can enhance SNR, their complexity significantly increases computational burden and limits their applicability to real-time or embedded imaging platforms.
In contrast, the proposed envelope-based preprocessing achieves a comparable SNR enhancement of approximately 9 dB using only a simple three-step operation: 1) analytic-signal generation via Hilbert transform, 2) envelope extraction, and 3) ON-OFF envelope averaging. This demonstrates that substantial performance improvement can be obtained with minimal algorithmic overhead, making the proposed method highly efficient in terms of SNR gain per processing complexity. Therefore, the proposed technique provides an effective front-end preprocessing solution that bridges the gap between a low-complexity detector readout and high-fidelity sub-THz imaging, enabling robust real-time operation without requiring complex post-processing pipelines.

IV. Conclusion

An envelope-based signal preprocessing method was presented to enhance the overall quality of sub-THz images acquired using a CMOS plasmonic detector. Unlike conventional peak detection, the proposed approach extracts smooth upper and lower envelopes from measured time-domain waveforms, thereby suppressing noise-induced fluctuations and reducing the impact of baseline drift. This enables more stable and reliable amplitude estimation throughout the imaging process. Experimental imaging results confirmed that the proposed preprocessing technique not only improves the measured SNR but also significantly enhances global image fidelity, spatial uniformity, and contrast consistency in reconstructed sub-THz images. By mitigating amplitude distortion caused by noise spikes, outliers, and DC offset drift, the proposed method reduces pixel-level intensity variations and suppresses artificial artifacts that degrade uniform-region consistency. Furthermore, the envelope-based preprocessing operates directly on the sampled detector waveform with minimal computational overhead, providing a practical front-end solution that eliminates the need for complex multi-stage post-processing. As a result, the proposed technique offers an efficient and robust pathway toward high-quality, real-time sub-THz imaging systems, particularly in applications requiring reliable amplitude extraction and stable spatial imaging performance. This work bridges the gap between compact CMOS sub-THz detector hardware and high-fidelity imaging requirements through complexity-efficient waveform-level preprocessing.

Notes

This work was supported by the Korean Government, Ministry of Trade, Industry, and Energy (No. 20026764). The chip fabrication and EDA tools were partly supported by the IC Design Education Center (IDEC), South Korea.

Fig. 1
Comparison of signal preprocessing methods for amplitude extraction from the modulated detector waveforms: (a) conventional peak detection and (b) proposed envelope-based detection.
jees-2026-5-r-384f1.jpg
Fig. 2
THz image reconstruction procedure using the proposed envelope-based detection method.
jees-2026-5-r-384f2.jpg
Fig. 3
Block diagram of the sub-THz imaging setup employing a CMOS plasmonic detector.
jees-2026-5-r-384f3.jpg
Fig. 4
Waveform analysis of a single pixel under modulated THz excitations: (a) ON-state and (b) OFF-state waveforms with conventional peak detection, and (c) ON-state and (d) OFF-state waveforms with the proposed envelope-based detection.
jees-2026-5-r-384f4.jpg
Fig. 5
Measurement results of sub-THz imaging: (a) photograph of the copper tape sample, (b) reconstructed image using peak detection, and (c) reconstructed image using the proposed envelope-based detection.
jees-2026-5-r-384f5.jpg
Table 1
Performance comparison of preprocessing techniques
Zhang et al. [18] Lee et al. [19] This work
Preprocessing technique Wavelet denoising ROI extraction Envelope detection
Frequency (THz) 1.34 0.2 0.15
Scanning type Raster scanning Line scanning Raster scanning
Process stepsa 6 7 3
SNR improvement (dB) 13.4 9.3 9

a Process steps estimated from the presented technique.

References

1. T. T. Nguyen, D. H. Kim, J. H. Choi, and C. W. Jung, "Circularly polarized series array and MIMO application for sub-millimeter wave/terahertz band," Journal of Electromagnetic Engineering and Science, vol. 24, no. 3, pp. 294–304, 2024. https://doi.org/10.26866/jees.2024.3.r.230
crossref
2. S. Oh, Y. Park, and J. Oh, "Sub-THz polarization-dependent beam-steerable metasurface antenna-in-package for 6G communication constructed using an LTCC process," Journal of Electromagnetic Engineering and Science, vol. 26, no. 1, pp. 88–102, 2026. https://doi.org/10.26866/jees.2026.1.r.342
crossref
3. X. Li, J. Li, Y. Li, A. Ozcan, and M. Jarrahi, "High-throughput terahertz imaging: progress and challenges," Light: Science & Applications, vol. 12, article no. 233, 2023. https://doi.org/10.1038/s41377-023-01278-0
crossref pdf
4. M. J. Lee, H. N. Lee, G. E. Lee, S. T. Han, D. W. Kang, and J. R. Yang, "CMOS detector staggered array module for subterahertz imaging on conveyor belt system," Sensors, vol. 23, no. 3, article no. 1232, 2023. https://doi.org/10.3390/s23031232
crossref pmid pmc
5. J. Hu, W. Liu, F. Xie, S. Xu, Z. Huang, and W. Li, "Study on imaging techniques and quantitative detection method for internal void defects in rubber based on terahertz reflection imaging," Optics Express, vol. 33, no. 7, pp. 15661–15681, 2025. https://doi.org/10.1364/OE.546988
crossref pmid
6. D. H. Choi, "Terahertz imaging of 100 μm scale subsurface defects in both depth and lateral directions in silicone rubber," Applied Optics, vol. 64, no. 25, pp. 7520–7526, 2025. https://doi.org/10.1364/AO.572596
crossref pmid
7. I. S. Lee, J. H. Park, and J. R. Yang, "Detrending technique for denoising in CW radar," Sensors, vol. 21, no. 19, article no. 6376, 2021. https://doi.org/10.3390/s21196376
crossref pmid pmc
8. A. Valles, J. He, S. Ohno, T. Omatsu, and K. Miyamoto, "Broadband high-resolution terahertz single-pixel imaging," Optics Express, vol. 28, no. 20, pp. 28868–28881, 2020. https://doi.org/10.1364/OE.404143
crossref pmid
9. J. Dong, X. Wu, A. Locquet, and D. S. Citrin, "Terahertz superresolution stratigraphic characterization of multilayered structures using sparse deconvolution," IEEE Transactions on Terahertz Science and Technology, vol. 7, no. 3, pp. 260–267, 2017. https://doi.org/10.1109/tthz.2017.2673542
crossref
10. W. Hu, Y. Li, Z. Han, Z. Xu, Y. Zhao, and J. Ni, "High-resolution range profile reconstruction method for terahertz FMCW radar," Applied Optics, vol. 60, no. 22, pp. 6400–6408, 2021. https://doi.org/10.1364/AO.431232
crossref pmid
11. A. Vergara, T. Tsukamoto, W. Fang, and S. Tanaka, "Design and fabrication of non-resonant PZT MEMS micromirror with buried piezoresistors for closed loop position control," Journal of Micromechanics and Microengineering, vol. 33, article no. 014001, 2023. https://doi.org/10.1088/1361-6439/aca101
crossref pdf
12. H. Nie, F. Hao, L. Wang, Q. Guo, H. Chen, J. Ren, and et al, "Application of terahertz nondestructive testing technology in the detection of polyethylene pipe defects," ACS Omega, vol. 8, no. 30, pp. 27323–27332, 2023. https://doi.org/10.1021/acsomega.3c02701
crossref pmid pmc
13. M. Dyakonov and M. Shur, "Shallow water analogy for a ballistic field effect transistor: New mechanism of plasma wave generation by DC current," Physical Review Letters, vol. 71, no. 15, pp. 2465–2468, 1993. https://doi.org/10.1103/PhysRevLett.71.2465
crossref pmid
14. J. A. Davis, D. E. McNamara, D. M. Cottrell, and J. Campos, "Image processing with the radial Hilbert transform: theory and experiments," Optics Letters, vol. 25, no. 2, pp. 99–101, 2000. https://doi.org/10.1364/ol.25.000099
crossref
15. H. N. Lee, H. J. Lee, S. T. Han, and J. R. Yang, "Highly sensitive CMOS plasmon detector with a low-gain buffer amplifier for terahertz imaging system," Microwave and Optical Technology Letters, vol. 63, no. 10, pp. 2587–2591, 2021. https://doi.org/10.1002/mop.32931
crossref
16. H. N. Lee, J. H. Yoon, and J. R. Yang, "A miniaturized plasmon detector using 0.25-μm CMOS process for large-scale sub-terahertz imaging," IDEC Journal of Integrated Circuits and Systems, vol. 9, no. 1, pp. 24–29, 2023. https://doi.org/10.23075/jicas.2023.9.1.005
crossref
17. H. N. Lee and J. R. Yang, "LC-enhanced CMOS plasmonic detector for sub-terahertz imaging," IEEE Microwave and Wireless Technology Letters, vol. 36, no. 2, pp. 245–248, 2026. https://doi.org/10.1109/lmwt.2025.3620269
crossref
18. Z. Zhang, Y. Lu, C. Lv, Q. Mao, S. Wang, and S. Yan, "Restoration of integrated circuit terahertz image based on wavelet denoising technique and the point spread function model," Optics and Lasers in Engineering, vol. 138, article no. 106413, 2021. https://doi.org/10.1016/j.optlaseng.2020.106413
crossref
19. H. N. Lee, Y. Park, J. T. Park, and J. R. Yang, "Signal preprocessing for foreign body detection using terahertz real-time non-destructive imaging system," PLOS One, vol. 20, no. 6, article no. e0319978, 2025. https://doi.org/10.1371/journal.pone.0319978
crossref

Biography

jees-2026-5-r-384f6.jpg
Ha-Neul Lee, https://orcid.org/0000-0002-8717-8455 received the B.S. and M.S. degrees in electronic engineering from Yeungnam University, Gyeongsan, South Korea, in 2019 and 2021, respectively, and the Ph.D. degree in electronic information and communication engineering from Konkuk University, Seoul, South Korea, in 2026. She is currently a Senior Researcher with LIG D&A, Yongin, South Korea. Her research interests include millimeter-wave and terahertz circuits and systems, with a focus on front-end integrated circuits and signal processing techniques for sub-terahertz imaging applications.

Biography

jees-2026-5-r-384f7.jpg
Hyeon Jin Son, https://orcid.org/0000-0002-4316-9282 received the B.S. degree in electronic engineering from Yeungnam University, Gyeongsan, South Korea, in 2022, and the M.S. degree in electronic information and communication engineering from Konkuk University, Seoul, South Korea, in 2025. From 2025 to 2026, he was a Researcher with Millisight Technologies Co., Ltd., Seoul, South Korea. He is currently an Engineer with Magnachip Semi-conductor Ltd., Cheongju, South Korea. His research interests include millimeter-wave and terahertz circuits and systems, particularly CMOS-based frequency generators and front-end integrated circuits for high-frequency sensing and communication systems.

Biography

jees-2026-5-r-384f8.jpg
Jong-Ryul Yang, https://orcid.org/0000-0003-4939-3274 received dual B.S. degrees in electrical engineering and materials science from Ajou University, Suwon, South Korea, in 2003, and the Ph.D. degree in electrical engineering and computer science from Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea, in 2009. From 2009 to 2011, he was a Senior Engineer with the System LSI Division, Samsung Electronics, Yongin, South Korea. From 2011 to 2016, he was a Senior Researcher with the Korea Electrotechnology Research Institute (KERI), Ansan, South Korea, where he also served as an Associate Professor with the University of Science and Technology (UST). From 2016 to 2023, he was an Associate Professor with Yeungnam University, Gyeongsan, South Korea. He is currently an Associate Professor with the Department of Electrical and Electronics Engineering, Konkuk University, Seoul, South Korea, and the Founder and Chief Executive Officer of Millisight Technologies Co., Ltd., established in 2023. His research interests include millimeter-wave and terahertz integrated circuits and systems, particularly CMOS-based detector and transmitter architectures, sub-terahertz imaging systems, advanced packaging, and radar-based sensing technologies for vital-sign monitoring and intelligent spatial sensing.
TOOLS
Share :
Facebook Twitter Linked In Google+
METRICS Graph View
  • 0 Crossref
  • 0 Scopus
  • 886 View
  • 59 Download
Related articles in JEES

ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-1101 Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Republic of Korea
Tel: +82-2-337-9666    Fax: +82-2-711-7550    E-mail: admin-jees@kiees.or.kr                

Copyright © 2026 by The Korean Institute of Electromagnetic Engineering and Science.

Developed in M2PI

Close layer
prev next