High-Gain Microstrip Antenna Based on Transmitting Focusing Metasurface for Dual-Circular Polarization
Article information
Abstract
In this work, a high-gain dual circular-polarization (CP) transmitting metasurface (MS) antenna is proposed that operates across both low- and high-frequency bands. A novel microstrip feed antenna (MFA) incorporating two coaxially fed tangential patches was initially introduced, radiating a left-hand circularly polarized (LHCP) wave with a gain of 4.32 dBic at approximately 8.7 GHz and a right-hand circularly polarized (RHCP) wave with a gain of 2.98 dBic at around 16.3 GHz. To enhance the performance of MFA, a transmitting MS engineered for dual-CP focusing effect was proposed. By positioning the MFA at the focal point of this transmitting MS, a dual-CP MS antenna system was developed to generate LHCP and RHCP radiations across two distinct frequency bands. This MS antenna achieves significantly enhanced gains of 15.9 dBic for LHCP at 8.7 GHz and 16.4 dBic for RHCP at 16.3 GHz. Experiments of the dual-CP MS antenna system align closely with numerical simulation results, validating the efficacy of the proposed design methodology.
I. Introduction
Circular-polarization (CP) antennas are critical for ensuring data connectivity in satellite communications and mobile platforms, as they effectively mitigate the Faraday rotation effect and multipath distortions [1, 2]. However, traditional CP antennas are often constrained by narrow bandwidths and low gains, restricting their application in modern wireless communication systems [3]. The rapid proliferation of wireless technologies, particularly in satellite and fifth-generation (5G) networks, demands antennas with high gain and compact form factors [4–7]. Microstrip antennas have gained widespread adoption due to their low profile and ease of integration. However, intrinsic limitations such as modest gain and challenges in achieving dual-CP radiation pose significant hurdles for their use in advanced systems requiring high-speed data transmission and robust interference immunity. Metasurfaces (MSs), composed of subwavelength unit cells, have emerged as a promising platform for constructing diverse functional devices, garnering increasing attention due to their ability to enable precise manipulation of electromagnetic (EM) waves across multiple dimensions [8–15]. MSs have facilitated the creation of high-performance microstrip antennas with unprecedented functional capabilities [16]. Recent breakthroughs in MSs have enabled innovative strategies to enhance antenna performance, driving progress across diverse applications [17–29]. Hussain et al. [17] introduced a low-profile and wideband CP patch antenna utilizing MSs, specifically designed for 5G communication systems. Liang et al. [27] introduced a lens antenna employing a four-layer phase-gradient MS to generate focused beams, which exhibited in-band measured gains ranging from 16.7 to 19.4 dBi and achieves a 3-dB gain bandwidth of approximately 10%. Although the reported MS antennas demonstrate exceptional performance across various EM radiation functionalities, most designs either focus on single-polarization operation or require complex feed networks, thereby limiting their versatility.
In recent years, extensive research has led to the development of various dual-band, multiband and dual-polarization MS antennas [30–34]. For example, Sun et al. [30] proposed a dual-polarization bidirectional focusing MS antenna. When integrated with a custom-designed microstrip feed antenna (MFA), this approach yielded an approximate 8 dBic gain enhancement for transmitted CP waves at 8.2 GHz and a roughly 10 dBi gain improvement for reflected linear polarization (LP) waves at 16.2 GHz compared to the standalone MFA [30]. Du et al. [32] presented a new dual-band aperture-shared base-station antenna array that uses a bifunctional MS to achieve broadband cross-band decoupling and maintain a low profile. This design provides stable radiation with ±45° dual-polarization across the frequency ranges of 0.67–0.98 GHz (37.6%) and 2.48–5.2 GHz (70.8%). Luo et al. [34] introduced a dual-frequency dual-CP antenna utilizing a Fabry-Perot (F-P) resonant cavity, which operates at a bandwidth of 4.77% (12.47–13.08 GHz) for low-frequency right-hand circularly polarized (RHCP) radiation and 5.36% (16.51–17.42 GHz) for high-frequency left-hand circularly polarized (LHCP) radiation. Nevertheless, existing designs often prioritize either LP or CP operation, falling short in achieving efficient dual-CP radiation within a low-profile architecture.
In this work, we introduce a new design of a dual-CP transmitting focusing MS integrated with a coaxial-fed MFA. The work is organized as follows. Firstly, we propose and demonstrate a dual-CP MFA capable of achieving simultaneous radiates LHCP and RHCP waves at lower frequency band and higher frequency band. Secondly, we have incorporated a dual-CP transmitting focusing MS that is specifically designed to concentrate both LHCP and RHCP waves within the two designated frequency bands. Thirdly, we have combined the dual-CP transmitting focusing MS with the MFA to develop a dual-CP MS antenna. The final experimental results of the designed dual-CP MS antenna show good alignment with simulations and demonstrate better performance than the MFA.
II. Dual-CP MFA
In this section, we introduced a dual-CP MFA. It is well-known that square patch antennas naturally emit LP waves; therefore, perturbation techniques are typically employed to achieve CP radiation [35]. The most common and practical method involves either trimming the corners of the patch or adding a rectangular diagonal slot [35–38]. Fig. 1(a) illustrates the geometry of the initial design for dual-CP MFA.
As demonstrated in Fig. 1(b), we truncated the corners of a square patch structure with a side length of l1 on the top layer, with each truncation having a size of m. This indicates the presence of an angular cut along the diagonal of the truncated square patch (TSP) structure located on the top layer. Simultaneously, as illustrated in Fig. 1(c), we incorporated a rectangular slot (RS) with dimensions n1×n2 into a TSP structure with a side length of l2 situated in the middle layer, meaning that a metal RS-TSP structure is adhered on the middle layer. Additionally, this MFA features a coaxial back-feed design, similar to those used in previous research [17, 20, 22, 30]. The MFA is designed to be fed via a coaxial back-feed, which has less impact on the radiation patch compared to the traditional microstrip side-feeding methods [23, 38, 39].
To assess the effectiveness of design, a comprehensive 3D full-wave EM simulation was carried out utilizing CST Microwave Studio, which is based on the finite integration technique (FIT). In simulation, open boundary conditions were applied around the MFA structure. Constraints included FR-4 (ɛr = 4.4, tanδ = 0.025) material properties, perturbation dimensions for dual-CP operation, and coaxial back-feed positioning to minimize pattern distortion. Noticed that the dual-CP MFA was rigorously optimized with key parameters systematically tuned to achieve an optimal balance among gain, bandwidth, and polarization purity. The ultimate optimized geometric parameters of the MFA are given as: l = 15 mm, l1 = 4.1 mm, l2 = 7.15 mm, m = 0.85 mm, n = 1.5 mm, h1 = 0.6 mm, h2 = 0.9 mm, d1 = 1.8 mm, d2 = 1.2 mm, d3 = 0.6 mm. The proposed dual-CP MFA was manufactured using conventional printed circuit board (PCB) technology. The radiation characteristics of the fabricated dual-CP MFA were measured using a vector network analyzer (Agilent E8362B) along with a standard antenna measurement system inside an anechoic chamber.
The testing sample for the proposed dual-CP MFA is presented in Fig. 2(a), which respectively display the front, middle, and back views, and the final sample. Fig. 2(b)–2(d) present the corresponding simulated and measured reflection coefficient (S11), axial ratio (AR) and gain at two different frequency regions. The measured results closely align with the simulated outcomes across the two target frequency ranges, with only minor amplitude discrepancies attributed to manufacturing tolerances, the welding process, and the testing environment. Fig. 2(b) illustrates that the measured (simulated) S11 stay under −10 dB within the frequency ranges of 8.15–9.35 GHz (8.27–9.34 GHz) and 15.55–18 GHz (15.83–17.28 GHz), indicating the dual-band low return loss of the designed MFA. As depicted in Fig. 2(c), both measured and simulated AR values are approximately 2.32 dB at 8.7 GHz and 2.01 dB at 16.3 GHz, respectively. This indicates that the MFA can effectively radiate CP waves in the vicinity of these frequencies. Evidently, the designed MFA is capable of attaining a dual-CP radiation property at the two targeted frequencies. Furthermore, as illustrated in Fig. 2(d), the designed MFA exhibits measured (simulated) gains of 4.32 (4.05) dBic and 2.98 (3.61) dBic for the CP waves at frequencies of 8.7 GHz and 16.3 GHz, respectively.
(a) The testing sample of the MFA, simulated and measured (b) reflection coefficient (S11), (c) axial ratio (AR), and (d) gain at two frequency regions.
As depicted in Fig. 3(a), at 8.7 GHz, the surface current induced on the middle layer of the RS-TSP structure exhibits an anti-clockwise rotation during the forward phase, which is indicative of LHCP radiation [17, 22–25]. As illustrated in Fig. 3(b), at 16.3 GHz, the situation is reversed: the induced surface current with an advancing phase on the TSP structure rotates clockwise, indicating RHCP radiation. This implies that the designed MFA is capable of efficiently radiating dual-CP waves, specifically LHCP at 8.7 GHz and RHCP at 16.3 GHz, respectively. The observed profile characteristics of the surface current distribution, featuring an advancing phase, further support the dual-CP nature of the MFA across these two frequency bands [17, 22–25].
Simulated surface current distributions on (a) the middle layer RS-TSP structure at 8.7 GHz and (b) the top layer TSP structure at 16.3 GHz of the proposed dual-CP MFA. The red arrow line presents the flow direction of the surface current.
To provide a comprehensive illustration of the radiation characteristics of the dual-CP MFA, we present the simulated and measured 2D far-field radiation patterns, as depicted in Fig. 4. It is evident that the measured results largely align with the simulated outcomes, albeit with minor fluctuations. These discrepancies may arise from the compact size of the original MFA, which poses challenges in securely mounting it on the rotation axis during far-field pattern measurements. At 8.7 GHz and 16.3 GHz, the MFA exhibits a hemispherical radiation pattern, with energy distribution being relatively dispersed. This indicates a lower level of directionality for the dual-CP wave radiations. Obviously, the designed MFA can radiate dual-CP waves at two different frequencies.
III. Dual-CP Transmitting Focusing MS
Integrating a functional MS into a conventional MFA represents a practical strategy to enhance the radiation performance of the designed antenna system [18, 20, 22, 27–30, 33]. Here, we introduce a novel design for a transmitting focusing MS tailored to dual-CP waves across lower and higher frequency regions. This section focuses on designing a MS that enables the transmission of dual-CP waves with a focusing effect, utilizing geometric phase modulation principles [11, 40–42]. When passing through the proposed MS structure, the incident CP wave can be converted to the opposite helicity. Additionally, the output wave experiences an extra phase shift of ϕ = ±2θ, where θ is the self-rotated angle of the resonator. The plus “+” or minus “−” sign indicates the helicity of RHCP or LHCP incidence, respectively. Fig. 5(a)–5(c) illustrate the front, back, and perspective views of the unit-cell structure for the dual-CP transmitting focusing MS. This MS features a bilayer metal resonator configuration situated on both the front and back layers of an intermediate dielectric substrate. The intermediate dielectric layer is made of Rogers-4350B with a relative permittivity of 3.66 and a loss tangent of 0.037. In the design of the unit-cell, the inverted outer split-ring resonators (SRRs) serve as the exterior component of the metallic structure, responsible for modulating the amplitude and phase of the transmitted LHCP waves within the lower frequency band. Meanwhile, the innermost segment, comprising reversed oval-shaped patches with rectangular slot resonators (OSP-RSRs), is tasked with regulating the amplitude and phase of the transmitted RHCP waves at the higher frequency band. As illustrated in Fig. 5(a) and 5(b), along the -z-axis direction, the rotation angle of the inverted outer SRRs with respect to the x-axis is denoted as θ2, whereas the rotation angle of the inner reversed OSP-RSRs with respect to the y-axis is designated as θ1. In the design of a dual-CP focusing MS, achieving independent phase modulation at two distinct frequencies by merely incorporating two independent resonators within the same unit-cell is challenging due to the significant interference between them. Consequently, a middle circular ring has been devised and implemented to mitigate crosstalk and interference between the transmitted RHCP and LHCP waves within the designated frequency bands. By leveraging the geometric phase principle, incident RHCP or LHCP waves propagating through the engineered MS are converted into LHCP or RHCP waves, respectively. This dual-CP conversion is achieved with a full 0–2π phase coverage and consistent transmission amplitudes, exclusively through adjusting the orientation of the bilayer metal resonators.
(a) The front, (b) back, and (c) perspective views of the unit-cell of the focusing MS, (d, e) transmission coefficient and (f, g) phase of the (d, f) LHCP wave in the lower frequency band and (e, g) RHCP wave in the higher frequency region.
Following careful optimization, the final geometric parameters of the MS unit-cell are as follows: t = 2 mm, p = 10 mm, g = 1 mm, r1 = 4.5 mm, r2 = 3.5 mm, r3 = 2.6 mm, r4 = 1.1 mm, w = 0.5 mm, a = 0.4 mm, b = 0.2 mm. As demonstrated in Figs. 5(d)–5(g), by modulating θ1 and θ2 from 0° to 150° in 30° increments, the corresponding transmission coefficients and phases for both LHCP and RHCP waves can be effectively and independently controlled. Specifically, as illustrated in Fig. 5(d) and 5(f), by adjusting only θ1 while θ2 was kept unchanged, the transmission coefficient of the LHCP wave remains constant at approximately 0.85 around 8.7 GHz, while achieving a 0 to 2π phase coverage through uniform phase variations. Conversely, as shown in Fig. 5(e) and 5(g), by adjusting only θ2 while θ1 was held constant, the transmission coefficient of the RHCP wave remains constant and above approximately 0.84 around 16.3 GHz, while also achieving complete phase coverage from 0 to 2π. By conducting field simulations, we can gain deeper insights into the distinct CP conversion performance achieved by our designed MS unit cell structure across different frequency bands. The instantaneous induced electric field (|E|) distributions of the front layers of the proposed MS unit-cell are shown in insets of the Fig. 5(d) and 5(e), respectively, with the LHCP at 8.7 GHz and RHCP wave at 16.3 GHz. It can be observed clearly that the instantaneous induced electric fields (|E|) of LHCP wave and RHCP wave are mainly concentrated and distributed on the SRRs structure at 8.7 GHz and OSP-RSRs structure at 16.3 GHz, respectively, implying typical dipolar resonance responses [20, 30]. Clearly, the coupling between two independent resonators is weak; thus, the discretionary wavefront manipulation for transmitted dual-CP waves can be achieved easily by rotating the resonator structures independently. The proposed MS is capable of simultaneously regulating LHCP and RHCP waves across two distinct frequency bands, thus fulfilling the need for an independent dual-CP transmitting focusing MS [40, 41].
In accordance with the geometric phase modulation principle, the unit-cells are systematically arranged in a regular pattern to form the dual-CP focusing MS. The theoretical focal length should be chosen to align with the target operating wavelengths (8.7 GHz and 16.3 GHz), ensuring effective concentration of radiated energy from the MFA placed at this focal point. This choice will ensure the MFA, when placed at the focal point, efficiently couples with the MS to achieve high-gain dual-CP radiation. The corresponding front and back views of the focusing MS are depicted in Fig. 6(a) and 6(b), respectively, and it occupies a total area of 130 mm × 130 mm. The phase compensation ϕ(x, y) along the x- and y-axes for the dual-CP transmitting focusing MS can be represented as [40, 41]:
(a) The front and (b) back views of the transmitting focusing MS, the corresponding phase distribution of LHCP wave at (c) 8.7 GHz and RHCP wave at (d) 16.3 GHz.
where λ denotes the operation wavelength of the incident CP waves in free space, and F stands for the focal length of the dual-CP transmitting focusing MS.
Based on Eq. (1), the final designed MS focuses the energy of incoming CP waves onto focal points in transmission mode, enabling dual-CP radiation at both lower and higher frequencies. To provide a more intuitive visualization of the phase corresponding to each unit-cell in the designed MS, Fig. 6(c) and 6(d) depict the phase distributions of the transmitted orthogonal LHCP wave at 8.7 GHz and RHCP wave at 16.3 GHz, respectively.
At 8.7 GHz and 16.3 GHz, as observed in Fig. 7(a) and 7(d), the focal lengths of the transmitted LHCP and RHCP waves are approximately 57.1 mm and 60.5 mm, respectively, closely matching the theoretical value of 60 mm. As shown in Fig. 7(b) and 7(e), distinct hotspots are clearly visible at the center of the xoy plane (focal plane) for the transmitted LHCP and RHCP waves at 8.7 GHz and 16.3 GHz, respectively. This indicates that when the incident RHCP and LHCP waves pass through the designed MS, they become transmitted LHCP and RHCP waves, effectively concentrating and focusing on a single point. Fig. 7(c) and 7(f) show that the full width at half maximum (FWHM) of the electric intensity along the x-axis for transmitted LHCP and RHCP waves are 33.6 mm and 11.8 mm, respectively. The focal length F was optimized to maximize gain while minimizing spherical phase error across the MS aperture. Noticed that the numerical analysis involved sweeping the focal length parameter from 40 mm to 80 mm while monitoring the resulting simulated gain. Our choice of F = 60 mm was the optimum from our parametric sweep, balancing these competing factors to maximize overall aperture efficiency and gain.
IV. Dual-CP Transmitting Focusing MS Antenna
In this section, the proposed initial MFA is positioned 60 mm away from the center of the designed MS along the +z-axis direction, thereby forming a dual-CP focusing MS antenna, as illustrated in Fig. 8(a). It can be expected that this MS antenna can effectively radiate high-gain LHCP and RHCP waves at the lower and higher frequency regions, respectively. The fabricated sample of the MS is shown in Fig. 8(b) and 8(c), which show the front and back views, respectively. The fabricated MS with size of 130 mm × 130 mm was ultimately optimized to meet the phase-compensation requirements for dual-band focusing, achieve maximum gain enhancement within fabrication constraints, align with the MFA’s radiation characteristics, and ensure practical feasibility for real-world applications.
Illustrations of (a) the proposed MS antenna, (b, c) the front and back view of the fabricated MS sample, (d, e) the anechoic chamber testing environment.
Fig. 8(d) and 8(e) illustrate the anechoic chamber testing environment, testing setup along with the measured MS antenna sample and ultra-broadband CP planar helix reference antenna (HD-20180PSAS; 2–18 GHz). This system integrates microwave foam as a supportive structure positioned between the MFA and the transmitting focusing MS. The MS is mounted securely, with its front surface facing the MFA to facilitate optimal wave transmission and focusing. A CP planar helix antenna is placed 3.5 m away from the MFA, satisfying the far-field measurement conditions. The entire setup is housed within an anechoic chamber to minimize external interference and ensure accurate measurement results. The radiation performance of this dual-CP MS antenna system was subjected to both simulation and measurement. The S11 and radiation characteristics of the engineered dual-CP MS antenna were assessed utilizing an Agilent E8362B vector network analyzer, in conjunction with a measurement system situated within an anechoic chamber.
Fig. 9 illustrates the simulated and measured S11, the values of the AR and gain of the proposed dual-CP MS antenna. The measured outcomes align closely with the simulated results, with any deviations primarily attributable to imperfections in manufacturing and assembly processes, variations in welding techniques, as well as environmental interferences encountered during the testing phase of the dual-CP MS antenna. The dual-CP MS antenna exhibited a high degree of consistency between simulated and measured results across its resonance frequencies, as well as within adjacent frequency bands. Fig. 9(a) illustrates that the measured (simulated) S11 values are less than −10 dB across the frequency intervals of 8.15–9.35 GHz (8.27–9.34 GHz) and 15.55–18 GHz (15.63–17.22 GHz). These values exhibit a close correspondence with those of the original MFA. It is important to note that there is a slight variation in the S11 of the dual-CP MS antenna system when compared to the initial MFA. This deviation can be attributed to the parasitic coupling effect that occurs between the MS and the MFA. The results mentioned above confirm that the engineered dual-CP MS antenna system can be precisely customized to support the two intended frequency bands.
The measured and simulated (a) reflection coefficient (S11), (b) axial ratio and (c) gain of the proposed dual-circular polarization transmitting MS antenna.
From Fig. 9(b) and 9(c), the measured (simulated) values of ARs are less than 3 dB at 7.91–8.95 GHz (7.95–9.15 GHz) and 15–17.5 GHz (15–17.21 GHz), respectively. Furthermore, the measured and simulated dip values of the ARs are approximately 1.23 dB and 0.14 dB at 8.7 GHz and 16.3 GHz, respectively. This implies that the dual-CP attributes of the MS antenna remain largely unaltered in comparison to the MFA. Notably, at this juncture, the dual-CP MS antenna emits a LHCP wave at 8.7 GHz and a RHCP wave at 16.3 GHz. This phenomenon arises from the cross-polarization conversion of the EM waves radiated by the MFA as they traverse the focusing MS. Noticed that the flat AR response from 15–17.5 GHz arises from the MS unit-cell design, which ensures stable transmission and phase modulation for RHCP waves across the band, combined with the MFA’s intrinsic RHCP radiation at higher frequencies, collectively maintaining CP purity over a broad range. Given that the dual-CP focusing MS can convert the spherical waves emitted by the original MFA at the focal point into plane waves [40, 41], the gain of the dual-CP MS antenna demonstrates substantial enhancements over the MFA across both operational frequency bands. As depicted in Fig. 9(c), the measured (simulated) gain of the dual-CP MS antenna reaches up to 15.9 (15.7) dBic at 8.7 GHz and 16.4 (16.4) dBic at 16.3 GHz, respectively, signifying a notable improvement when compared to the MFA. After integrating the focusing MS, the dual-CP MS antenna achieves a gain improvement of more than 11.58 dBic at 8.7 GHz for LHCP radiation and surpasses 13.42 dBi at 16.37 GHz for RHCP radiation. The incorporation of the focusing MS substantially enhances the gain augmentation of the proposed dual-CP MS antenna.
Fig. 10 presents the simulated and measured 2D far-field radiation patterns of the dual-CP MS antenna in both the E-plane and H-plane, specifically at frequencies of 8.7 GHz and 16.3 GHz, respectively. This provides additional evidence that the proposed dual-CP MS antenna exhibits directional radiation characteristics tailored to dual-CP radiation at two distinct frequencies. To some degree, the measured far-field radiation pattern is influenced by interference originating from clutter within the test environment and noise generated by the test system, resulting in a jagged, sawtooth-like distortion. While this leads to some discrepancies compared to the simulated outcomes, the general trend remains consistent.
Simulated and measured far-field radiation patterns of the dual-CP MS antenna: (a) E-plane and (b) H-plane at 8.7 GHz and (c) E-plane and (d) H-plane at 16.3 GHz.
The aforementioned simulated and measured data demonstrate that the MS antenna possesses the capability to emit LHCP and RHCP waves at two distinct frequencies, respectively, thereby achieving high-gain dual-CP radiation. Experimental results demonstrate that the dual-CP focusing MS efficiently directs microwave energy into a focused beam in transmission mode, achieving the desired performance at approximately 8.7 GHz for LHCP waves and 16.3 GHz for RHCP waves. It has been experimentally verified that MS antenna demonstrates pronounced back-lobe radiation patterns, which can be attributed to multiple design-specific parameters and inherent system constraints. The substantial back-lobe radiation is reasonably attributed to three primary factors:
The inherently dispersed hemispherical radiation characteristics of MFA design, since the MFA exhibits a hemispherical radiation pattern with inherent backward leakage (measured back-lobe level: approximately 8 dBic at 16.3 GHz, as shown in Fig. 4(d)).
The MS antenna's primary optimization for forward beam focusing with inadequate consideration for backward radiation suppression, since the MS is primarily optimized for forward beam focusing, and its design does not explicitly incorporate mechanisms for backward radiation suppression.
The compact integration of the MFA (size: 15 mm × 15 mm) and MS (size: 130 mm × 130 mm) at a 60 mm separation induces parasitic coupling between the MFA’s coaxial feed and the MS’s layers. These identified factors collectively correlate well with the experimentally observed radiation pattern characteristics.
To demonstrate the advantages of the designed antenna, a comparative analysis with prior research is presented in Table 1, highlighting key performance improvements in polarization characteristics, peak gain, MS size relative to the wavelength, the distance between the MS and the feed antenna (F/D2). Compared with previous designs [27–31], the proposed dual-CP MS antenna does not require the addition of additional nonlinear elements, and smaller value of F/D2 meaning the more compact focusing configuration. Compared to designs in Refs. [30, 31], the proposed MS antenna exhibits a higher gain, while achieving smaller MS size than those in Refs. [28, 29]. There is no doubt that our proposed dual-CP MS antenna design significantly outperforms other congeneric products in terms of dual-polarization radiation and high-gain implementation, with excellent overall performance.
V. Conclusion
In conclusion, we have successfully developed and validated a dual-CP MS antenna system that significantly enhances the radiation performance of a custom MFA. The integrated MS antenna system achieves LHCP with a peak gain of 15.9 dBic at 8.7 GHz and RHCP with a peak gain of 16.4 dBic at 16.3 GHz. When compared to the standalone MFA, the incorporation of the dual-CP transmissive focusing MS delivers a substantial performance improvement, elevating LHCP gain by approximately 11.58 dBic at 8.7 GHz and RHCP gain by 13.43 dBic at 16.3 GHz, respectively. The proposed dual-CP MS antenna system demonstrates robust high-gain, dual-CP radiation capabilities, offering a practical and efficient solution for advanced communication systems requiring dual-CP and high-speed data transmission.
Notes
This work was supported by the Science and Technology Research project of Education Department of Hubei province (Grant No. B2023137).
References
Biography
![]()
Xia Cao, https://orcid.org/0000-0002-4600-4037 received her Ph.D. degree in radio physics from Huazhong Normal University in 2022. Currently, she serves as a lecturer at the School of Physics and Electronic Science, Hubei Normal University, China. Her research focuses on electromagnetic metamaterials, MIMO antennas, and embedded systems.
![]()
Lingling Yang, https://orcid.org/0009-0002-2827-1921 received her Ph.D. in microelectronics and solid state electronics from Huazhong University of Science and Technology (HUST), China, in 2017. From 2022, she is a full associate professor in Wuhan Vocational College of Software and Engineering (Wuhan Open University), China. She is also appointed as an expert in Hubei Engineering Research Center for Intelligent Detection and Identification of Complex Parts. She has authored over 30 peer-reviewed journal articles. Her current research interests include areas of microwave, metamaterial or metasurface micro-wave devices including filter, antenna, divider, etc.
![]()
Yibo Sun, https://orcid.org/0009-0003-2544-1339 received the M.S. degree in Information and Communication Engineering from Wuhan University of Science and Technology, Wuhan, China, in 2025. He is currently a RF engineer. His current research interests include metasurface antenna, and RCS reduction for antenna application.
![]()
Zhigang Cheng, https://orcid.org/0009-0009-7743-1136 received his M.S. degree in control theory and control engineering from the Wuhan University of Technology (WUT), Wuhan, China, in 2022. Now he is a lecture with the Hubei Vocational College of Railway Transportation (Wuhan Railway Technician College). His main research includes power electronics, industrial internet of things, wireless sensor networks, and metamaterials.
![]()
Yongzhi Cheng, https://orcid.org/0000-0003-4928-9872 received his Ph.D. in microelectronics and solid state electronics from Huazhong University of Science and Technology(HUST), China, in 2015. From 2013–2014, he worked as a visiting Ph.D. student in T-ray Labs of the University of Adelaide, where he studied and designed metamaterial plasmonic devices for terahertz waves. From 2022, he is a full professor in Wuhan University of Science and Technology (WUST), China. For one year from 2022–2023, he is a guest professor in EM Labs of Nagoya Institute of Technology (NIT), Japan. His current research interests include areas of microwave, terahertz, optical and physics, metamaterial or metasurface microwave devices including filter, antenna, absorber, etc. He is selected the Elsevier highly cited Chinese researchers in 2020–2024, China 2020–2023 top cited paper award in IOP Publishing’s physics journals, 2022 best paper award article (rank 1) in an Open Access Journal Materials, and the Electronics 2024 Young Investigator Award by MDPI. He has authored over 200 peer-reviewed journal articles, which have been cited by more than 14620 times (H-factor 71; Google Scholar). He served as a guest editor for Nanomaterials (Open Access Journal by MDPI) on special issue in 2022.
