Correlating Fully Anechoic Chamber to Open Area Test Site Measurements by the Normalized Site Attenuation
Tae-Weon Kang1, Byung-Wook Kim2, Yeon-Choon Chung3, Hyo-Tae Kim4
1Korea Research Institute of Standards and Science, Electromagnetics Group
2Department of Electronics Engineering Sogang university
3Expan Electronics Components Corporation
4Department of Electrical and Electronic Engineering Pohang, University of Science and Technology
Abstract
The performance of a fully anechoic chamber (FAC) for radiated emission (RE) measurements has been evaluated using the normalized site attenuation (NSA). To do this, the antenna factor (AF) of a set consisting of nearly identical antennas has been calibrated at an open area test site (OATS). Appropriate correlation factor (CF) between the chamber and the OATS has been calculated. Results show that the performance of the chamber is fairly good with respect to the ANSI-limit except 41~66 MHz far vertical polarization and near 900 MHz for horizontal polarization.
Key words: correlation, normalized site attenuation, radiated emission, open area test site, fully anechoic chamber
TOOLS
Share :
Facebook Twitter Linked In Google+
METRICS Graph View
  • 1,143 View
  • 9 Download
Related articles in JEES

ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
#706 Totoo Valley, 217 Saechang-ro, Yongsan-gu, Seoul 04376, Korea
Tel: +82-2-337-9666    Fax: +82-2-6390-7550    E-mail: admin-jees@kiees.or.kr                

Copyright © 2024 by The Korean Institute of Electromagnetic Engineering and Science.

Developed in M2PI

Close layer
prev next